"Configuration" Details ICHIB-C1

This setting is explained in two parts :" Read and write"


1, the parameter used when reading

1:page size(The SFF protocol requires the value to be set to: 8 bytes, but there are exceptions, you can try other values)

2:ReadIIc(This value can be set in the range of 0-10, the smaller the faster. Can be set according to experience)

Generally, no password is required for reading. However, there are exceptions, and this is generally only the case in the custom area of the SFF protocol

123.png


2, the parameter used when Writeing

1:page size (The SFF protocol requires the value to be set to: 8 bytes, but there are exceptions, you can try other values)

2:WriteIIc (This is a wide range of values that we've used from 0 to 999.  Usually values of 50, 100, and 200 are tested first.)

3:ReadIIc(This value can be set in the range of 0-10, the smaller the faster. Can be set according to experience)(The value is also used by the Verify in Write Options)

4:PW Add (According to the SFF agreement, SFP fill in A27B XFP,QSFP fill in A07B, QSFP-DD fill in A07A)
(Please consult the supplier first when filling in the address, not all manufacturers will be set according to the regulations)

5:PW(Consult the optical module supplier)

Generally, no password is required for reading. However, there are exceptions, and this is generally only the case in the custom area of the SFF protocol

124.png

After all the values are set, all the values are saved to the file with the extension ini through the "Save as" function (the folder can be customized for more calls).

扫描二维码推送至手机访问。

版权声明:本文由IICHIB发布,如需转载请注明出处(如有版权异议,请联系我们)。

严禁使用IICHIB所有设备及相关程序从事任何非法活动.

违法和不良信息举报中心.

本文链接:https://iichib.com/post/76.html

分享给朋友:

“"Configuration" Details ICHIB-C1” 的相关文章

XFP optical module Read Digital Diagnostic Monitoring(DDM/DOM)

XFP optical module Read Digital Diagnostic Monitoring(DDM/DOM)

The hardware device in this demonstration is 10G-XFP-SRAll XFP packaged fiber modules can be used for referencePrepare multi-mode optical fiber module...

Optical module coding illustrated tutorial - English (continuous update)

This manual is applicable to ICHIB-X1 and X2 series (ICHIB-X1 series only has read and write code function, and cannot realize laser operation and DDM...

SFP optical module Read Digital Diagnostic Monitoring(DDM/DOM)

SFP optical module Read Digital Diagnostic Monitoring(DDM/DOM)

The hardware device in this demonstration is 1.25G-SFP-SXAll SFP packaged fiber modules can be used for referencePrepare multi-mode optical fiber modu...

QSFP-DD optical transceiver reads the firmware

QSFP-DD optical transceiver reads the firmware

The hardware device in this demonstration is 400G-QSFP-DD-DF4All QSFP-DD packaged fiber modules can be used for referenceAfter the software opens, log...

Local File Selection function description

Local File Selection function description

The four open buttons in the local file selection correspond to the hexadecimal editor. (After the file is imported, it can be edited and used. You ca...